Menu
  • Home
  • Universal Panel Configuration Guide

Universal Panel Configuration Guide

17 Panels in 1

Our NEW Universal Panel is backwards compatible with all standard tank types.

Available in 2 form factors, on tank (1500) and remote (2500),  pre-wired for all model types.

On Tank

Remote

STEP 1: Accessing the Configuration Port

Perform configuration prior to installation.  With power disconnected, begin by rotating the panel to the bottom side.

Locate the configuration access port cover.  Using a flat head screw driver, carefully loosen one edge of the plastic snap-in cover.

Once loose, remove the plastic snap-in cover by hand.  Retain the plastic cover, as it should be reinstalled after configuration.

STEP 2: Wiring & Configuration

Verify the configuration based on your existing tank type using the charts below!

DIP SWITCH ON/OFF

  1. Push to Pump Button Momentary/Timer function
  2. Enable/Disable Push to Pump Button
  3. Enable/Disable Call for Pickup Audible Alarm
  4. Enable/Disable Tank Full Audible Alarm

TURN DIAL (TIMER CONTROL)
DIP 1 must be off for timer.  Adjustment from a minimum of 3 minutes (counter clockwise) to a maximum of 30 minutes (clockwise) run time.  The timer can be disabled by the operator at any point by pressing the Push to Pump button while the timer is engaged.

Model C - Wiring & Configuration

Applies to: 700111 (1500C), 700115 (2500C), 700450 (OD BOSS)

POWER IN

HEAT

PROBE

NOT USED
KEEP CAPPED

NOT USED
KEEP CAPPED

Model H - Wiring & Configuration

Applies to: 700113 (1500H), 700116 (2500H)

POWER IN

HEAT

PROBE

NOT USED
KEEP CAPPED

BALL VALVE

Model CH - Wiring & Configuration

Applies to: 700183 (1500CH), 700184 (2500CH)

POWER IN

HEAT

PROBE

MOTOR

BALL VALVE

Model D - Wiring & Configuration

Applies to: 700112 (1500D), 700115 (2500D)

POWER IN

HEAT

PROBE

MOTOR

NOT USED
KEEP CAPPED